1 zones, Zone/overtravel parameters chapter 6, Figure 6.2 programmable zone 2 – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 129

Advertising
background image

Zone/Overtravel Parameters

Chapter 6

6-3

When you select the “Zone/Overtravel Parameters” group from the main

menu in AMP, the workstation displays this screen:

Proj:

AMPTEST

Appl:

AMP

Util:

Edit

F2-Project F3-Application F4-Utility

F5-Configuration

F1-File

F2-Axis

F3-Options

F4-Quick Edit!

F5-Process

Type : Lathe

AXIS: X <P1> - linear

P1:

File :

TEST

- Zone/Overtravel Parameters -

Programmable Zone group axis (1)

:

Belongs to no group

Number of Limit 2,3 groups <P1>

:

0

Limit 2 max value (1)

:

0.00000 mm

Limit 2 min value (1)

:

0.00000 mm

Limit 3 max value (1)

:

0.00000 mm

Limit 3 min value (1)

:

0.00000 mm

Software Overtravel Used (1)

:

True

Positive Software Overtravel (1)

:

0.00000 mm

Negative Software Overtravel (1)

:

0.00000 mm

First Interf. Check Axis <P1>

:

X

Second Interf. Check Axis <P1>

:

Z

Interference

Axes

Orientation

:

First Opp., Second Same Dir.

Max Interference Check Zones <P1>

:

8

Your screens may differ slightly, depending on your application type.

The control can have two programmable zones into or out of which the
tool is not permitted to move. A typical configuration of zone 2 is shown

in Figure 6.2:

Figure 6.2

Programmable Zone 2

Z

X

Machine

coordinate

zero

Min X

value

Max X

value

Max Z

value

Min Z

value

Min Y

value

Max Y

value

Y

X

Programmable Zone 2

as defined by minimum

and maximum axis values

Zone 2 defines an exterior zone (tool must stay outside of the zone

boundaries). This zone is enabled or disabled by part program commands.

6.1

Zones