Power-up G-code Parameters
Chapter 19
19-4
Function
This parameter selects the default G-code for modal group 6. The selected
G-code specifies whether the control operates under inch or metric mode at
power -up only. A control reset will not re-establish this mode. The last
programmed state remains in effect.
Lathe
A
Lathe
B
Lathe
C
Mill
Control
Surface
Grinder
Cylindrical
Grinder
Active Mode
G20
G20
G70
G20
G70
G70
Inch system
G21
G21
G71
G21
G71
G71
Metric system
Axis
Parameter Number
Single Process
Process 1
Process 2
All
[526]
[20526]
[21526]
Range
Selection
Result
(a)
Inch mode
(b)
Metric mode
Notes
This is a global parameter. The value set here applies to all axes.
For dual--processing controls, this is a per process parameter. The value set
in the parameters applies to all of the axes assigned to that process.
19.3
PTO G- code For Modal
Group 6