6 tolerance band distance (d) – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 584

Advertising
background image

Probing Parameters

Chapter 31

31-6

Function

This parameter is used by both the G38 and G38.1 probing cycles.

The value entered for this parameter defines a tolerance band on either side

of the coordinate of the expected firing point (as entered in the probing

cycle block) for the probe. Enter a value for this parameter “D” that

defines a tolerance distance on either side of the expected firing point of

the probe. This value is added to and subtracted from the expected firing

point of the probe making the band width twice this value. This parameter

is an unsigned value.

If the probe does not fire within the tolerance band defined by this

parameter, a PROBE ERROR occurs.

This parameter may also be entered directly in the probing cycle block of

the part program with a “D” word. If the “D” word is present in the

probing cycle block, the value entered here is ignored.

Axis

Parameter Number

Single Process

Process 1

Process 2

All

[604]

[20604]

[21604]

Range

0.00000 to 99999.00000 mm

or

0.00000 to 3936.96850 in.

Notes

This is a per process parameter. The value set here applies to all axes

assigned to that process.

This parameter may also be changed on the control by using the fixed

cycle parameter table.

This parameter is for mill and surface grinder applications only.

31.6

Tolerance Band Distance (D)

Advertising