Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 162

Advertising
background image

Servo Parameters

Chapter 7

7-16

Range

Servo Loop Type:

Results in:

CNC generates:

(a) None

Control behaves as if that servo is detached.

--

(b) Position or
Analog Spindle

Select this as the servo loop type for analog drive

systems that have an external tachometer mechanically

coupled to the motor shaft. Feedback from this

tachometer is typically returned to the servo amplifier to

close the velocity loop (see Figure 7.6). Can also be

used if the position loop is open or detached.

position command

(c) Position/Velocity

The control closes the velocity loop. Separate devices

or the same feedback device can be used to close both

the position and velocity loops. This is typical of

tachless analog servo systems (see page 7-17).

Important:

This selection is not applicable on the

9/440 high--resolution CNC. Any attempt to use this

selection with a 9/440 high--resolution results in the

error, “VEL LOOP INVALID WITH DAC OUT”.

torque command

(d) Digital or Digital

Spindle

The control closes the position and velocity loop. Motor

information necessary for proper commutation is

provided for digital drive systems. Can be used for

8520drive/8500motor or 1394 drive/1326 motor

systems. Must be selected for all digital systems,

including the 9/440, 9/230 Digital, and 1394 systems

used as digital spindles.

Important:

Analog systems can not use a tachometer

for velocity feedback to the control. Only encoder

signals can be used for feedback to the 9/Series CNC.

Both the velocity feedback and positioning feedback for

an axis must be returned to the same servo module as

the servo’s output port.

digital command

(current)

Important: For more detailed information regarding Servo Loop Type,

refer to page 7-4.

Notes

This parameter must be set independently for each servo.

Important: The servo loop type, “Position/Velocity” is not applicable to

the 9/440 high--resolution device. Any attempt to select this servo loop

type will result in the error, “VEL LOOP INVALID WITH DAC OUT.”

Once you have configured both the “Servo Hardware Type” and the “Servo

Loop Type” additional parameters to configure that specific servo system

become available.

Advertising