Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 719

Patch AMP
Chapter 41
41-17
Parameter
Patch AMP Value
Default Value
Parameter Name
1201
2201
3201
Maximum cutting feedrate
42.33333 mm/sec
0.00000 to 169.33333 mm/sec
1202
2202
3202
ACC/DEC ramp
27.12674 mm/s/s
0.00000 to 9999.99999 mm/s/s
1203
2203
3203
Rapid feedrate for positioning
169.33333 mm/sec
0.00000 to 4064.00000 mm/sec
1204
2204
3204
Velocity step for ACC/DEC
4.23333 mm/sec
0.00000 to 169.33333 mm/sec
1210
2210
3210
Linear Acceleration Ramp
25.4 mm/sec/sec
0.00000 to 20,000.00000 mm/sec/sec
1211
2211
3211
Linear Deceleration Ramp
25.4 mm/sec/sec
0.00000 to 20,000.00000 mm/sec/sec
1212
2212
3212
S--Curve Acceleration Ramp
25.4 mm/sec/sec
0.00000 to 20,000.00000 mm/sec/sec
1213
2213
3213
S--Curve Deceleration Ramp
25.4 mm/sec/sec
0.00000 to 20,000.00000 mm/sec/sec
1214
2214
3214
Axis Jerk
5.08 mm/sec/sec/sec
0.00000 to 1,000,000.0000
mm/sec/sec
1215
2215
3215
Minimum Programmable Jerk
5.08 mm/sec/sec/sec
0.00000 to 1,000,000.0000
mm/sec/sec
1300
2300
3300
Home Calibration
0.00000 mm
--999999.99000 to 999999.99000 mm
1310
2310
3310
Axis Position after Homing
0.00000 mm
--2540000.00000 to 2540000.00000
mm
1320
2320
3320
Positive Software Overtravel
0.00000 mm
--2540000.00000 to 2540000.00000
mm