Key down displays the second page – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 688

Tuning AMP at the Machine
Chapter 40
40-10
Important: If the rotary axis does not have a net amount of zero
calibration, the control will still allow this calibration to be applied to
the axis.
If data has been previously entered, the control displays a screen that list
the axis calibration points. This screen is a typical axis calibration screen.
Figure 40.2
Typical Online Axis Calibration Screen
AXIS CALIBRATION
PAGE
1 OF
2
X AXIS - 0.1230
[ MM ]
ABSOLUTE
DEVIATION
1
-76543.218
- 2.345679
2
-65432.187
0.345678
3
-54321.876
- 1.456717
4
-43218.756
1.234566
5
-32187.654
0.123455
6
-21876.543
- 0.345674
7
-18765.432
- 1.567893
8
- 7654.321
- 1.678902
9
- 6543.217
0.789121
10
-
654.321
0.912340
11
-
54.321
- 1.234561
12
-
4.321
0.789122
23 POINTS USED FOR AXIS X
905 FREE
REPLCE
VALUE
INSERT
POINT
DELETE
POINT
UPDATE
& EXIT
NEXT
AXIS
Important: An axis may have more than one screen of measurement
points assigned to it. If there is more than one page, pressing the down
cursor while holding the
[SHIFT]
key down displays the second page.