Key down displays the second page – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 688

Advertising
background image

Tuning AMP at the Machine

Chapter 40

40-10

Important: If the rotary axis does not have a net amount of zero

calibration, the control will still allow this calibration to be applied to

the axis.

If data has been previously entered, the control displays a screen that list

the axis calibration points. This screen is a typical axis calibration screen.

Figure 40.2

Typical Online Axis Calibration Screen

AXIS CALIBRATION

PAGE

1 OF

2

X AXIS - 0.1230

[ MM ]

ABSOLUTE

DEVIATION

1

-76543.218

- 2.345679

2

-65432.187

0.345678

3

-54321.876

- 1.456717

4

-43218.756

1.234566

5

-32187.654

0.123455

6

-21876.543

- 0.345674

7

-18765.432

- 1.567893

8

- 7654.321

- 1.678902

9

- 6543.217

0.789121

10

-

654.321

0.912340

11

-

54.321

- 1.234561

12

-

4.321

0.789122

23 POINTS USED FOR AXIS X

905 FREE

REPLCE

VALUE

INSERT

POINT

DELETE

POINT

UPDATE

& EXIT

NEXT

AXIS

Important: An axis may have more than one screen of measurement

points assigned to it. If there is more than one page, pressing the down

cursor while holding the

[SHIFT]

key down displays the second page.

Advertising