Pal parameters, 0 chapter overview 20.1 pal background interval, Chapter – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 451: Function, Range

Advertising
background image

Chapter

20

20-1

PAL Parameters

This chapter covers the PAL parameters. Use these parameters to specify
PAL related options that are machine-dependant. Access these parameters

by selecting the PAL Parameters group from the AMP main menu.

The workstation displays this screen when the “PAL Parameters” group

is selected:

Proj:

AMPTEST

Appl:

AMP

Util:

Edit

F2-Project F3-Application F4-Utility

F5-Configuration

F1-File

F2-Axis

F3-Options

F4-Quick Edit!

Control Type:

Mill

Axis :

X - linear

File :

TEST

- PAL Parameters -

PAL background interval

:

50 msec

PAL Only Axis (1)

:

False

PAL $AOUT00-analog output port

:

No output

PAL $AOUT01-analog output port

:

No output

PAL $AOUT02-analog output port

:

No output

PAL $AOUT03-analog output port

:

No output

Function

Use this parameter to specify the time limit for the PAL background

program execution. The PAL background program restarts at the end of

the specified time limit. If it does not execute to completion within the

specified time limit, a bit is set in the PAL flag $PLFT. See your PAL

reference manual for details.

Refer to your PAL reference manual for important guidelines on setting

this parameter.

Parameter Number

[69]

Range

30 to 10000 msec

20.0

Chapter Overview

20.1

PAL Background Interval