OCI Parameters

Chapter 38

38-2

Function

This parameter specifies the number of PCs that can connect and create

watchlists on the 9/Series CNC. Any PC that connects to the CNC through

the OCI interface creates a watchlist to access data. This does not include

ODS workstations that may connect through the Ethernet interface to

upload/download PAL, AMP, or part programs.

Axis

Parameter

Number

All

[332]

Range

1 to 4 OCI stations

Notes

All PCs that ask for manual items create a watchlist which is cleared after

the data is passed back to the PC.

This parameter directly impacts the amount of memory your CNC allocates

for OCI station watchlists. You should set this value as low as possible to

provide the control with as much operating memory as possible (large

watchlist creation can adversely impact the number of available setup

buffers on your system). Space is allocated for all watchlist connections

available (as specified by this parameter), regardless of if a PC is actually

connected and using the watchlist. In the event that not enough room is

available to create the specified watchlists at power up, the CNC will only

create the first watchlist buffer and the control is held in E--Stop.

Watchlists are created sequentially. If you specify 2 OCI connection

allowed with this parameter, only two watchlist data buffers 1 and 2 can be

created on the CNC. If your data server OCIDSCFG.INI file specifies a

specific data buffer to connect to, make sure that data buffer is created with

this parameter. (i.e. in the above case of 2 maximum number of OCI

connections if the data servers INI file specifies data buffer 3 for that

connecting station an error is generated even though no other OCI

connections may currently exist to that CNC and watchlist data buffers 1

and 2 are empty).

This is a global parameter; the value set here applies to all axes

and processes.