Chapter

41

41-1

Patch AMP

Use of the Patch AMP utility requires access to the highest user level, plus
a special second password.

ATTENTION: Altering AMP through the Patch AMP utility

bypasses the system software that checks AMP parameters. You

can enter illegal and/or dangerous values that will not generate

an error. Illegal or dangerous values can cause negative

changes to a machine responding to motion commands. This

can result in damage to the part or the machine, or injury to

an operator.

The Patch AMP utility is softkey selectable; but due to the danger
associated with changing AMP data without any cross-reference checking,

the utility is “double” password protected. Only the highest level user will

see the

{PATCH AMP}

softkey, and another password must be entered before

that softkey will function.

Important: AMP is typically entered by the system installer and should

not require changes once the control is installed and the machine is

running. Most users should not be permitted access to AMP parameters.

The Patch AMP utility is used to modify the Adjustable Machine

Parameters (AMP) directly on the control. This gives the machine tool

builder the flexibility to change AMP without connecting an ODS

workstation (personal computer) to the control.

Important: For Dual Process controls, Patch AMP is independent of the

selected process. It shows parameters for both processes at the same time.

41.0

Patch AMP

41.1

Accessing Patch AMP