Feedrate Parameters

Chapter 9

9-6

Function

Use this parameter to set a value for the first position of the Rapid Feedrate

Override switch (labeled F1 on the MTB panel). Enter a percent value for

this parameter. The value for the other three switch positions is determined

in PAL. The axis travels in normal rapid positioning (G00) mode at the

Rapid Feedrate for Positioning multiplied by the percent value entered here

when the Rapid Feedrate override switch is set to F1.

Axis

Parameter

Number

All

[67]

Range

0% to 100%

Notes

When a value of 0% is set for this parameter, the Rapid Feedrate for

Positioning is reduced to 0 and, in effect, places the control in “Feedhold.”

No axis motion takes place.

When the control powers up F1 is the default feedrate override on a

push-button MTB panel.

This parameter in no way relates to the single-digit “Feedrate for F1”

parameter.

This is a global parameter. The value set here applies to all axes.