background image

Servo Parameters

Chapter 7

7-35

Function

The value entered here sets the furthest distance the axis can be from its

commanded destination to be considered in position when the control is in

G00 (rapid mode), G09 (exact stop nonmodal), G61 (exact stop modal), or

when homing.
This does not affect the final positioning accuracy of the system. It simply

determines how close to the endpoint of a move the axis must be before the

next move can begin.

Important: The value entered here must be less than the value entered for

Gain Break Point or a Warning: “SERVO AMP FE LIMITS

CORRECTED” occurs. However, if the value entered here is too small,

inherent axis and feedback instability may prevent the axis from ever

reaching the commanded position (including home position).

Important: In the event that you have a split axis, both servos must be

within their inposition bands before the control determines the axis

inposition.

Figure 7.20

Axis In-Position Band

Commanded

axis position

INPOSITION BAND

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1735]

(7)

[7735]

(2)

[2735]

(8)

[8735]

(3)

[3735]

(9)

[9735]

(4)

[4735]

(10)

[10735]

(5)

[5735]

(11)

[11735]

(6)

[6735]

(12)

[12735]

Range

0 to 214.10000 mm
or
0 to 8.42913 in.

Notes

This parameter must be set independently for each servo.

7.2.7

Inposition Band