11 default orient direction – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 343

Advertising
background image

Spindle 1 Parameters

Chapter 12

12-15

Function

This parameter specifies the direction the spindle rotates during:

any open loop spindle orient

any closed loop spindle orient that takes place before the spindle has
found a marker.

Spindle is:

Encoder Marker

is:

The Orient is Performed in the

Direction:

closed loop

already found

that would yield the shortest path

to the orient position

closed loop

not yet found

as specified with this parameter

open loop

N/A

as specified with this parameter

If a closed loop spindle is already turning when an orient request is made,

the spindle will decelerate (or accelerate) to the AMP defined orient

spindle speed and orient to the requested location (this parameter has no

affect on the spindle direction). Closed loop spindles only use this

parameter if it has not yet seen a marker. Typically this is only after a

power up cycle before the spindle has been moved. If there is no S word

in the closed loop spindle orient block (M19), the spindle rotates to the

position defined by the Default Orient Angle parameter.

Open loop spindles always use this parameter to determine spindle

direction for an orient operation. The spindle will orient to the specified

location in open loop orient position in the direction specified with this

parameter (even if the spindle is already rotating in the opposite direction).

The direction entered here overrides the setting of the PAL flag “Spindle

Direction” ($SPNDI) during execution of an M19. $SPNDI usually checks

the spindle direction switch or button on the MTB panel to determine

spindle direction.

Refer to your programming and operation manuals for more complete

information on spindle orient.

Spindle

Parameter

Number

1

[851]

12.11

Default Orient Direction