Zone/Overtravel Parameters

Chapter 6

6-11

Function

Use this parameter to enter the larger machine coordinate value that

determines the location of programmable zone 3. This value may be

altered on the control, if desired, by using the programmable zone table or

by the proper programming commands. The area defined as

programmable zone 3 limits axis motion according to the position of the

axis when the zone is activated.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1007]

(7)

[7007]

(2)

[2007]

(8)

[8007]

(3)

[3007]

(9)

[9007]

(4)

[4007]

(10)

[10007]

(5)

[5007]

(11)

[11007]

(6)

[6007]

(12)

[12007]

Range

Limit 3 Min value to 999999.99000 mm

or

Limit 3 Min value to 39370.07835 inch

The range of this parameter is dependent on the value set for the parameter

“Limit 3 Min value.”

Notes

This parameter must be set independently for each axis.

6.1.5

Limit 3 Max Value