5 limit 3 max value – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 137
Zone/Overtravel Parameters
Chapter 6
6-11
Function
Use this parameter to enter the larger machine coordinate value that
determines the location of programmable zone 3. This value may be
altered on the control, if desired, by using the programmable zone table or
by the proper programming commands. The area defined as
programmable zone 3 limits axis motion according to the position of the
axis when the zone is activated.
Axis
Parameter
Number
Axis
Parameter
Number
(1)
[1007]
(7)
[7007]
(2)
[2007]
(8)
[8007]
(3)
[3007]
(9)
[9007]
(4)
[4007]
(10)
[10007]
(5)
[5007]
(11)
[11007]
(6)
[6007]
(12)
[12007]
Range
Limit 3 Min value to 999999.99000 mm
or
Limit 3 Min value to 39370.07835 inch
The range of this parameter is dependent on the value set for the parameter
“Limit 3 Min value.”
Notes
This parameter must be set independently for each axis.
6.1.5
Limit 3 Max Value