OCI Parameters

Chapter 38

38-5

The following parameters allow the configuration of the watchlist buffer
sizes. One parameter is available to select the foreground watchlist buffer

size for all connected OCI stations. Separate parameters are available for

each background watchlist created by connected OCI stations.

Important: We recommend not changing the defaults on any of these

watchlist buffer sizes. The default values for these watchlists are

acceptable for most applications including the BDS.

At power up the control does a memory allocation. Space for two

watchlists (one foreground and one background) is reserved for each OCI

station that can connect to your CNC (see the parameter “Maximum

Number of OCI Connections”). The more memory that is allocated for

watchlist space, the less memory that is available for other CNC functions.

The result is the control will begin to remove setup buffers for part

program execution when the watchlist buffer size is allocated as too large.

The available amount of memory on any given system depends on the

processor, features enabled, and memory upgrade options you have

purchased for the machine.

When the control has insufficient memory to create at least five setup

buffers, the control is held in E--Stop. When this occurs only watchlist #1

is created and the error message “Not Enough Setup Buffers” is returned.

Important: You can assign an OCI station to a specific watchlist buffer

when the OCI stations data server is configured. The parameter

“OCIDataBuffer” in the OCIDSCFG.INI file selects the watchlist for that

OCI station on the CNC. See your 9/Series OCI installation manual for

details. To identify the “Not Enough Setup Buffers” error your OCI station

must connect to watchlist 1.