background image

Tuning AMP at the Machine

Chapter 40

40-16

4.

When you have configured more than one spindle, the

{NEXT SPINDL}

prompt highlights. Use this softkey to toggle through

the various spindles you have configured.

5.

Press the

{UPDATE & EXIT}

softkey to save the modified spindle

parameter values. The control then returns to softkey level 4.

Press the

{QUIT}

softkey to return to softkey level 4 without saving

any changes.

One of the softkeys displayed after accessing the online AMP softkeys is
the

{UPDATE BACKUP}

softkey. This softkey is used to backup AMP or axis

calibration data to or from the control’s memory.

The control displays this screen when the

{UPDATE BACKUP}

softkey

is pressed:

STORE TO BACKUP

AMP
AXIS CALIBRATION

SELECT OPTION USING THE UP/DOWN ARROW

TO

BACKUP

FROM

BACKUP

Use the up or down cursor keys to highlight the type of information that is

to be backed up to or from the control’s memory.

To backup information to the control’s flash memory from the control’s

RAM memory, press the

{TO BACKUP}

softkey. The selected information,

AMP or axis calibration data, is copied from the control’s RAM memory to

the control’s flash memory.

40.7

Backup to Memory