Tuning AMP at the Machine
Chapter 40
40-16
4.
When you have configured more than one spindle, the
{NEXT SPINDL}
prompt highlights. Use this softkey to toggle through
the various spindles you have configured.
5.
Press the
{UPDATE & EXIT}
softkey to save the modified spindle
parameter values. The control then returns to softkey level 4.
Press the
{QUIT}
softkey to return to softkey level 4 without saving
any changes.
One of the softkeys displayed after accessing the online AMP softkeys is
the
{UPDATE BACKUP}
softkey. This softkey is used to backup AMP or axis
calibration data to or from the control’s memory.
The control displays this screen when the
{UPDATE BACKUP}
softkey
is pressed:
STORE TO BACKUP
AMP
AXIS CALIBRATION
SELECT OPTION USING THE UP/DOWN ARROW
TO
BACKUP
FROM
BACKUP
Use the up or down cursor keys to highlight the type of information that is
to be backed up to or from the control’s memory.
To backup information to the control’s flash memory from the control’s
RAM memory, press the
{TO BACKUP}
softkey. The selected information,
AMP or axis calibration data, is copied from the control’s RAM memory to
the control’s flash memory.
40.7
Backup to Memory