3 velocity step for acc/dec – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 303

Advertising
background image

Acc/Dec Parameters

Chapter 10

10-7

Axis

Parameter

Number

Single Process

All

[402]

Notes

This is a global parameter. The value set here applies to all axes.

Axis jogging moves use either linear or exponential Acc/Dec as defined in

AMP via Manual Acc/Dec (refer to page 10-19 for more information about

Manual Acc/Dec). Axis cutting moves use Linear or S--Curve Acc/Dec.

Function

If two adjacent motion blocks in a program require different axis feedrates,

Acc/Dec may be necessary to smooth the speed transition. The value

entered for this parameter specifies the maximum change in feedrate that

will be executed without any Acc/Dec activated.

For example, entering 50 mmpm here, means that any feedrate changes

equal to or less than 50 mmpm will be executed as a step, with no

Acc/Dec. Acc/dec ramping will be used for any feedrate transitions greater

than 50 mmpm.

ATTENTION: Entering too large a value here may result in

damage to the part, tooling, or machine. Large changes in

feedrate should always be made gradually when using Acc/Dec.

For most axis configurations, this value should be less than or equal to the

value entered for the Acc/Dec Ramp parameter.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1204]

(7)

[7204]

(2)

[2204]

(8)

[8204]

(3)

[3204]

(9)

[9204]

(4)

[4204]

(10)

[10204]

(5)

[5204]

(11)

[11204]

(6)

[6204]

(12)

[12204]

10.3

Velocity Step for ACC/DEC