Acc/Dec Parameters
Chapter 10
10-22
R
T
= -----
and
J
R
J
Max
= ------
where JMax = 2 scans (0.04 s) and
T
Min
R
J
Min
= ------
where J
Min
= 60 scans (1.20 s)
T
Max
Where :
Is :
J
Axis jerk value
R
Ramp value
T
S--Curve time per system scan rate
1,2
1
Time is in seconds.
2
Maximum S--Curve time = 1.20 s (60 scans at 20 ms scan rate)
Minimum S--Curve time = 0.04 s (2 scans at 20 ms scan rate)
Refer to the table below for examples of resulting jerk values, given
R, T, and the system scan rate:
Ramp Value
S--Curve Time
per System Scan
Rate
Coarse Foreground
Scan Time
Axis Jerk Value
1,000 ipm/s
0.04 s
20 ms
25,000 ipm/s/s (max)
1.20 s
833 ipm/s/s (min.)
0.16 s
6,250 ipm/s/s
(example per
machine parameters)
2,500 ipm/s
0.028 s
14 ms
89,286 ipm/s/s (max)
0.84 s
2,976 ipm/s/s (min.)
0.112 s
22,321 ipm/s/s
(example per