Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 318

Advertising
background image

Acc/Dec Parameters

Chapter 10

10-22

R

T

= -----

and

J

R

J

Max

= ------

where JMax = 2 scans (0.04 s) and

T

Min

R

J

Min

= ------

where J

Min

= 60 scans (1.20 s)

T

Max

Where :

Is :

J

Axis jerk value

R

Ramp value

T

S--Curve time per system scan rate

1,2

1

Time is in seconds.

2

Maximum S--Curve time = 1.20 s (60 scans at 20 ms scan rate)

Minimum S--Curve time = 0.04 s (2 scans at 20 ms scan rate)

Refer to the table below for examples of resulting jerk values, given

R, T, and the system scan rate:

Ramp Value

S--Curve Time

per System Scan

Rate

Coarse Foreground

Scan Time

Axis Jerk Value

1,000 ipm/s

0.04 s

20 ms

25,000 ipm/s/s (max)

1.20 s

833 ipm/s/s (min.)

0.16 s

6,250 ipm/s/s

(example per

machine parameters)

2,500 ipm/s

0.028 s

14 ms

89,286 ipm/s/s (max)

0.84 s

2,976 ipm/s/s (min.)

0.112 s

22,321 ipm/s/s

(example per

machine parameters)