Home Parameters

Chapter 5

5-2

This chapter covers the AMP parameters that are used in homing the axes.
These parameters are significant for both manual and automatic

axis homing:

Parameter:

Page:

Dir. to Move Off Limit Switch

5-10

Home Calibration

5-11

Axis Position after Homing

5-12

Home Speed from Limit Switch

5-14

The following outlines how a typical homing operation functions for
incremental systems. Systems with absolute multiturn encoders (available

on some 1326 servo motors) that are compatible with 9/Series do not

require a homing sequence after initial integration. If you have a system

with a distance--coded marker (DCM) linear feedback device, refer to

page 5-8 for details.

The following procedure applies to revision software 13.x or greater.

Refer to page 5-4 if the software revision of your system is 12.x or

earlier:

1.

Set the Mode Select switch to “Manual,” and the Jog Select switch to

“Home” (assuming the Standard MTB Panel is being used).

2.

Press the appropriate Axis/Direction button to move the axis in the

direction of the home limit switch. Initial speed for this move can be

selected through the use of the jog speed and feedrate override

switches.

Once the homing sequence is initiated, the jog speed switch has no

effect on the speed of the axis. However, the feedrate override switch

still effects speed.

ATTENTION: Some mechanical switches will turn “OFF” at a

different location when approached from different directions.

In those cases, it is essential that the home limit switch be

approached from the same direction every time the axis is

homed. This can be assured by proper switch positioning, PAL

programming, AMP programming and/or operator instruction.

5.1

Homing Concepts

5.1.1

Manual Homing Using a

Home Switch