Tuning AMP at the Machine

Chapter 40

40-17

To backup information from the control’s flash memory to the control’s

RAM memory, press the

{FROM BACKUP}

softkey. The selected

information, AMP or axis calibration data, is copied from the control’s

flash memory to the control’s RAM memory.

The control displays the message “PLEASE POWER DOWN AND

RESTART”. The control must be turned off and then on again after the

information is backed up from flash memory to RAM.

One of the softkeys displayed after accessing the online AMP softkeys is
the

{UPLD/DWNLD}

softkey.

This softkey is used to upload or download PAL and I/O files or AMP

files. Refer to your PAL reference manual for more information on

uploading or downloading PAL and I/O files.

Uploading and downloading AMP files is covered in these sections:

Downloading AMP Files

Uploading AMP Files

Important: Refer to chapter 2 for information on downloading AMP from
the workstation to the control or uploading AMP from the control to

the workstation.

To download an AMP file from a storage device to the control:

At the storage device:

1.

Connect the storage device to the control.

Refer to your integration and maintenance manual for more information

on cabling.

2.

Set the baud rate switch to “1200.”

3.

Set the track select switch to “Continuous.”

40.8

Uploading and Downloading

AMP

40.9

Downloading AMP Files