Jog Parameters
Chapter 8
8-14
Function
The value specified for this parameter is equal to the distance that an
incremental jog move travels when <SPEED/MULTIPLY> on the MTB
panel is set to LOW X1.
Axis
Parameter Number
Axis
Parameter Number
(1)
[1360]
(7)
[7360]
(2)
[2360]
(8)
[8360]
(3)
[3360]
(9)
[9360]
(4)
[4360]
(10)
[10360]
(5)
[5360]
(11)
[11360]
(6)
[6360]
(12)
[12360]
Range
0.00010 mm or .0001 degree to Second Jog Increment value
or
0.00000 inch to Second Jog Increment value
The maximum value that may be set for this parameter is dependant on the
value set for the parameter “Second Jog Increment.”
Notes
You must set this parameter independently for each axis.
The default setting for <SPEED/MULTIPLY> on the pushbutton MTB
panel is LOW X1.
8.4.1
Smallest Jog Increment