1 smallest jog increment – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 272

Advertising
background image

Jog Parameters

Chapter 8

8-14

Function

The value specified for this parameter is equal to the distance that an

incremental jog move travels when <SPEED/MULTIPLY> on the MTB

panel is set to LOW X1.

Axis

Parameter Number

Axis

Parameter Number

(1)

[1360]

(7)

[7360]

(2)

[2360]

(8)

[8360]

(3)

[3360]

(9)

[9360]

(4)

[4360]

(10)

[10360]

(5)

[5360]

(11)

[11360]

(6)

[6360]

(12)

[12360]

Range

0.00010 mm or .0001 degree to Second Jog Increment value

or

0.00000 inch to Second Jog Increment value

The maximum value that may be set for this parameter is dependant on the

value set for the parameter “Second Jog Increment.”

Notes

You must set this parameter independently for each axis.

The default setting for <SPEED/MULTIPLY> on the pushbutton MTB

panel is LOW X1.

8.4.1

Smallest Jog Increment