background image

Tuning AMP at the Machine

Chapter 40

40-21

This screen is displayed on the operator panel CRT:

ACTIVE COPY PARAMETERS

FROM:

AMP

TO:

PORT A (or PORT B)

DEVICE:

ALLEN-BRADLEY 1770-SB

BAUD RATE:

1200

PARITY:

NONE

STOP BITS:

1

DATA LENGTH:

8

YES

NO

If you want:

Press this softkey:

the control to upload the AMP file to the

storage device

{YES}

the upload procedure to abort

{NO}

One of the softkeys displayed after accessing the online AMP softkeys is
the

{BACKUP AMP}

softkey. This softkey is used to back up these

AMP parameters:

Home Calibration parameters

Reversal Error parameters

Axis Calibration parameters

Important: The home calibration and reversal error parameter data may

only be backed up to a printer. The axis calibration parameter data may be

backed up to or from a storage device.

40.11

Backup AMP