Tuning AMP at the Machine
Chapter 40
40-21
This screen is displayed on the operator panel CRT:
ACTIVE COPY PARAMETERS
FROM:
AMP
TO:
PORT A (or PORT B)
DEVICE:
ALLEN-BRADLEY 1770-SB
BAUD RATE:
1200
PARITY:
NONE
STOP BITS:
1
DATA LENGTH:
8
YES
NO
If you want:
Press this softkey:
the control to upload the AMP file to the
storage device
{YES}
the upload procedure to abort
{NO}
One of the softkeys displayed after accessing the online AMP softkeys is
the
{BACKUP AMP}
softkey. This softkey is used to back up these
AMP parameters:
Home Calibration parameters
Reversal Error parameters
Axis Calibration parameters
Important: The home calibration and reversal error parameter data may
only be backed up to a printer. The axis calibration parameter data may be
backed up to or from a storage device.
40.11
Backup AMP