Spindle 2 Parameters

Chapter 13

13-15

Function

This parameter determines the spindle speed in RPM that the control uses

when positioning the spindle during a spindle orient (M19).

Refer to your programming and operation manual for more information on

spindle orient.

Parameter

Number

[864]

Range

0.0 to 99999.9 rpm

Notes

The orient speed is usually a very low value to assure that the spindle

moves accurately to the orient position.

Executing an M19 may force a gear change to a different gear range to

accommodate the speed entered here.

This parameter must be set for each spindle axis.

This feature is not available on the 9/230 control.

Function

This parameter specifies the direction the spindle rotates during a spindle

orient (M19).

When an M19 is executed in the part program or through MDI, the spindle

rotates in the direction entered here to the position defined by the S word

in the M19 block (if there is no S word in the block, the spindle rotates to

the position defined by the Default Orient Angle parameter).

The direction entered here overrides the setting of the PAL flag “Spindle

Direction” during execution of an M19. This flag usually checks the

spindle direction switch on the MTB panel to determine spindle direction.

Refer to your programming and operation manual for more information on

spindle orient.

13.10

Orient Speed

13.11

Default Orient Direction

Advertising