10 uploading amp files – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 697

Advertising
background image

Tuning AMP at the Machine

Chapter 40

40-19

This screen is displayed on the operator panel CRT:

ACTIVE COPY PARAMETERS

FROM:

PORT A (or PORT B)

TO:

AMP

DEVICE:

ALLEN-BRADLEY 1770-SB

BAUD RATE:

1200

PARITY:

NONE

STOP BITS:

1

DATA LENGTH:

8

YES

NO

If you want:

Press this softkey:

the control to download the AMP file to the

storage device

{YES}

the download procedure to abort

{NO}

Important: Refer to chapter 2 for information on downloading AMP from
the workstation to the control or uploading AMP from the control to

the workstation.

Use this procedure to upload a file from the control to a storage device :

At the storage device:

1.

Connect the storage device to the control.

Refer to your integration and maintenance manual for more information

on cabling.

2.

Turn “ON” the storage device.

3.

Load an AMP data cassette into the storage device.

40.10

Uploading AMP Files