Using AMP Applications and ODS Utilities

Chapter 2

2-31

The operator panel CRT displays this screen:

Figure 2.5

Upload Parameter Screen

COPY PARAMETERS

FROM:

AMP

TO:

PORT A (or PORT B)

DEVICE:

ALLEN-BRADLEY 1770-SB

BAUD RATE:

1200

PARITY:

NONE

STOP BITS:

1

DATA LENGTH:

8

YES

NO

6.

Refer to the table below.

If you want to:

Press this softkey:

upload the stored AMP file from the control to

the storage device

{YES}

abort the upload procedure

{NO}

To upload an AMP file to the workstation from a storage device:

At the storage device:

1.

Connect a storage device to the workstation’s input/output port.

2.

Load the AMP data cassette, which contains the selected AMP file, in

the storage device.

3.

Set the baud rate to “9600.”

4.

Set the track select switch to “Continuous.”