5 high- speed input trigger point 37.6 dwell type – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 645

Advertising
background image

Miscellaneous Parameters

Chapter 37

37-5

Function

Use this parameter to determine when the control recognizes a high-speed

trigger signal from some external device to execute one of the skip or

probing functions. The control recognizes a high-speed trigger signal

when the signal is turned on or off.

Rising edge -- When this parameter is set at “Rising edge,” the control

recognizes a high-speed input signal when the probe turns on (rising edge

of the signal).

Falling edge -- When this parameter is set at “Falling edge,” the control

recognizes a high speed input signal when the probe turns off (falling edge

of the signal).

Axis

Parameter

Number

All

[3]

Range

Selection

Result

(a)

Rising edge

(b)

Falling edge

Notes

This is a global parameter; the value set here applies to all axes

and processes.

This parameter is not available on the 9/230 control.

Function

Use this parameter to force the control to execute only dwells (G04) in

units of seconds.

Time & Spn Revs -- When this parameter is selected as “Time & Spn

Revs,” a dwell may be programmed in second or in spindle revolutions.

Dwells that are programmed in G94 mode are in units of seconds, and

dwells that are programmed in G95 mode are in units of spindle

revolutions.

37.5

High- speed Input Trigger

Point

37.6

Dwell Type

Advertising