1 feed integral torque gain – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 588

Advertising
background image

Adaptive Feed & Depth Parameters

Chapter 32

32-2

Function

This parameter specifies the integral torque gain for an axis move that is

performed in adaptive feed mode. Refer to your 9/Series Mill Operation

and Programming Manual for details on this feature. This parameter is

only available on mill control types.

This parameter (in conjunction with the parameter Feed Proportional

Torque Gain) is used to determine the net change to the 9/Series feedrate

command. The feedrate override is modified in order to try to maintain a

constant torque. The desired torque is specified in the program block.

This parameter specifies the ratio of % change in feedrate to the existing

integrated torque error. When you increase the value of the Feed Integral

Torque Gain, it will cause the integrator to have a greater effect on the

adaptive feedrate. The integrator helps smooth out the response to

instantaneous changes in torque error smoothing out the 9/Series feedrate

commands.

Feed Integral Torque Gain

Axis number

Parameter

Number

Feed Integral Torque Gain

Axis number

Parameter

Number

Axis (1)

[1152]

Axis (7)

[7152]

Axis (2)

[2152]

Axis (8)

[8152]

Axis (3)

[3152]

Axis (9)

[9152]

Axis (4)

[4152]

Axis (10)

[10152]

Axis (5)

[5152]

Axis (11)

[11152]

Axis (6)

[6152]

Axis (12)

[12152]

Range

0.1 to 2.0

Notes

This parameter must be set independently for each axis.

32.1

Feed Integral

Torque Gain

Advertising