6 traverse jog speed – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 281

Advertising
background image

Jog Parameters

Chapter 8

8-23

Function

The value specified for this parameter is equal to the speed at which a

continuous jog move takes place when the traverse jog speed is selected

(typically this is selected by holding down the <TRVRS> button when

jogging). This traverse feedrate may be modified by the operator using the

<RAPID FEEDRATE OVERRIDE> switch.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1003]

(7)

[7003]

(2)

[2003]

(8)

[8003]

(3)

[3003]

(9)

[9003]

(4)

[4003]

(10)

[10003]

(5)

[5003]

(11)

[11003]

(6)

[6003]

(12)

[12003]

Range

0.00600 mmpm to 10160.00004 mmpm

or

0.00024 ipm to 400.00000 ipm.

Notes

This parameter must be set independently for each axis.

END OF CHAPTER

8.6

Traverse Jog Speed

Advertising