Tuning AMP at the Machine

Chapter 40

40-12

Calibration Status On/Off

Axis calibration is turned on whenever an axis is homed. When the axis

calibration is on for an axis the

{CAL STATUS}

softkey is shown in reverse

video.

It is often helpful to turn axis calibration off when inserting a calibration

point. With calibration off, you can more accurately determine the axis

position without accounting for previously entered calibration points.

Press the

{CAL STATUS}

softkey to turn axis calibration off for the selected

axis. Once turned off, you must home the axis again to turn axis

calibration back on.

(softkey level 4)

CAL

STATUS

REPLCE

VALUE

INSERT

POINT

DELETE

POINT

UPDATE

& EXIT

NEXT

AXIS

The online servo parameters are used to tune specific servo parameters.
Refer to chapter 7 for additional information on these parameters.

Use this procedure to access the online servo parameters:

1.

Press the

{AXIS PARAM}

softkey.

(softkey level 3)

AXIS

PARAM

PATCH

AMP

UPDATE

BACKUP

UPLD/

DWNLD

BACKUP

AMP

2.

Press the

{SERVO PARAM}

softkey.

(softkey level 4)

REVERS

ERROR

HOME

CALIB

AXIS

CALIB

SERVO

PARAM

SPNDL

PARAM

40.5

Online Servo Parameters