1 pulse count multipliers, Jog parameters chapter 8 – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 260

Advertising
background image

Jog Parameters

Chapter 8

8-2

After you select “Jog Parameters” from the main menu, these screens

become available:

Proj:

AMPTEST

Appl:

AMP

Util:

Edit

F2-Project F3-Application F4-Utility

F5-Configuration

F1-File

F2-Axis

F3-Options

F4-Quick Edit!

F5-Process

Control Type : Mill

Axis :

X - linear

File :

TEST

- Jog Parameters -

Page 2 of 2

Largest Jog Increment (1)

:

25.40000 mm

Jog Retract Velocity

:

253.9980 mmpm

Max Jogs in Retracts <P1>

:

15

Traverse Jog Speed (1)

:

3810.00000 mmpm

Proj:

AMPTEST

Appl:

AMP

Util:

Edit

F2-Project F3-Application F4-Utility

F5-Configuration

F1-File

F2-Axis

F3-Options

F4-Quick Edit!

F5-Process

Control: Mill

AXIS :

X - linear

File :

TEST

- Jog Parameters -

Page 1 of 2

Pulse Count Multiplier_Low (1) :

0.00254 mm

Pulse Count Multiplier_Med (1) :

0.02540 mm

Pulse Count Multiplier_High (1):

0.25400 mm

Arbitrary Joggable Axis (1)

:

True

Lowest Jog Speed (1)

:

2.54000 mmpm

Second Jog Speed (1)

:

25.40000 mmpm

Third Jog Speed (1)

:

253.99998 mmpm

Fourth Jog Speed (1)

:

2540.00000 mmpm

Highest Jog Speed (1)

:

10159.99980 mmpm

Smallest Jog Increment (1)

:

0.00254 mm

Second Jog Increment (1)

:

0.02540 mm

Third Jog Increment (1)

:

0.25400 mm

Fourth Jog Increment (1)

:

2.54000 mm

Use these three pulse-count multiplier parameters to set the resolution of
the hand pulse generator (HPG or handwheel):

Parameter:

Page:

Pulse count multiplier — low

8-3

Pulse count multiplier — med

8-4

Pulse count multiplier — high

8-5

The value specified for each of the three pulse-count multiplier parameters

is the distance that the axis moves for each pulse that is sent from the HPG.

These three parameters correspond to LOW X1, MEDL X10, and

MEDX100 of <SPEED/MULTIPLY> on the MTB panel when an HPG jog

is taking place.

Important: When <SPEED/MULTIPLY> is MEDH X1000 or

HIGH X10000, the handwheel is disabled.

The default setting for <SPEED/MULTIPLY> on the pushbutton MTB

panel is LOW X1.

8.1

Pulse Count Multipliers

Advertising