Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 511

Advertising
background image

Cutter Comp/Tool Tip Radius

Chapter 23

23-11

Function

Enter the vector distance from the end-point of a move that creates a

corner, to the point on the next move at which Automatic Corner Override

is to be deactivated.

(DFC stands for Distance From Corner)

Refer to the discussion of the AMP parameter Min Angle for Corner

Override for details.

This is not a per-axis parameter. The distance selected here is applied to

all axes.

Axis

Parameter

Number

All

[410]

Range

0.00000 to 9999.99999 mm

or

0.00000 to 393.70079 in

Notes

This is a global parameter. The value set here applies to all axes and

processes.

23.2.3

Corner Override Distance

(DFC)

Advertising