1 corner override angle – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 509
Cutter Comp/Tool Tip Radius
Chapter 23
23-9
This set of parameters determines how the corner override feature operates.
They are described in detail on these pages:
Parameter:
Page:
Minimum Angle for Corner Override
23-9
Corner override distance (DTC)
23-10
Corner override distance (DFC)
23-11
Corner override %
23-12
Figure 23.4
Automatic Corner Override
Programmed feedrate
resumed here
CORNER OVERRIDE DISTANCE (DFC)
CORNER OVERRIDE DISTANCE (DTC)
b
CORNER OVERRIDE ANGLE (min.)
a
A
Feedrate reduced
here to percentage
indicated by parameter
CORNER OVERRIDE %
Function
Enter the minimum angle between two consecutive programmed moves (or
angle between tangent lines if moves are arcs) required before Automatic
Corner Override can be activated.
Axis
Parameter
Number
All
[28]
Range
0 to 180 degrees
23.2.1
Corner Override Angle