background image

Cutter Comp/Tool Tip Radius

Chapter 23

23-9

This set of parameters determines how the corner override feature operates.

They are described in detail on these pages:

Parameter:

Page:

Minimum Angle for Corner Override

23-9

Corner override distance (DTC)

23-10

Corner override distance (DFC)

23-11

Corner override %

23-12

Figure 23.4

Automatic Corner Override

Programmed feedrate

resumed here

CORNER OVERRIDE DISTANCE (DFC)

CORNER OVERRIDE DISTANCE (DTC)

b

CORNER OVERRIDE ANGLE (min.)

a

A

Feedrate reduced

here to percentage

indicated by parameter

CORNER OVERRIDE %

Function

Enter the minimum angle between two consecutive programmed moves (or

angle between tangent lines if moves are arcs) required before Automatic

Corner Override can be activated.

Axis

Parameter

Number

All

[28]

Range

0 to 180 degrees

23.2.1

Corner Override Angle