4 maximum motor speed – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 237

Advertising
background image

Servo Parameters

Chapter 7

7-91

Function

This parameter is not available for digital servos connected to the 4-axis

8520 digital servo card or to the 9/230 8520 digital CNC. It is used for

9/260 or 9/290 systems that use the 3-axis 8520 digital servo cards and

servo systems designed to connect to any 1394 digital system, including

the 9/440 CNC.

Enter the maximum motor speed (in RPM) that your motor/drive/load

combination allows.

The motor speed entered here should be approximately 10% above what

would be required for the axis to achieve its maximum feedrate.

Standard motor rated speeds and maximum speeds are shown in the motor

tables of your integration and maintenance manual. The correct value for

the selected motor should be entered here.

If a nonstandard motor is to be used, motor maximum speeds can be

obtained from the motor specification literature.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1580]

(7)

[7580]

(2)

[2580]

(8)

[8580]

(3)

[3580]

(9)

[9580]

(4)

[4580]

(10)

[10580]

(5)

[5580]

(11)

[11580]

(6)

[6580]

(12)

[12580]

Range

0 to 999999 rpm

Notes

This parameter must be set independently for each servo.

Digital Spindle users must set this parameter to determine the maximum

gear one motor speed in addition to configuring the spindle group

parameter “Maximum Spindle Speed -- Gear 1”. Also keep in mind the

maximum motor speed for a digital spindle using 1326 resolver based

systems set to use the higher available feedback resolution (32768 counts

per rev) is limited to 3000 RPM. If higher motor speeds are required for

your resolver based digital spindle use the lower (8192 counts per rev)

feedback setting for both velocity and position feedback.

7.4.4

Maximum Motor Speed

Advertising