Miscellaneous Parameters

Chapter 37

37-22

Figure 37.2

Scan Sequence of the Main CPU and I/O CPU in a 9/290

Servo Read

Servo Write

Part Program Decode

Display Update

Low Level Diagnostics

Servo Read

Axis Control

System Foreground

System Background

Critical Foreground

must be greater than 2ms

PAL

Foreground

Interpolation

I/O Ring Read/Write

PAL Background

Low Level Diagnostics

System Background Tasks

1.

I/O CPU begins

PAL Foreground

scan when Servo

Read is complete.

2.

Main CPU scans

background tasks while

I/O completes

PAL Foreground Scan

and Interpolation.

3.

When the I/O CPU completes Interpolation, the

Main CPU stops scanning background tasks and

scans Servo Write, Axis Control, etc. for the remainder

of the system scan. When all the time for a system scan

is spent, the control begins the sequence again.

Scan Sequence

of Main CPU

Scan Sequence

of I/O CPU

System Scan Time (6-30 ms; AMP selectable)

PAL

Foreground

PAL

Foreground

Using the System Timer Screen

You can use the system timer screen to determine how long it takes the

control to scan the tasks in the system foreground. To display this screen:

1.

Press the [SYSTEM SUPORT] softkey.

2.

Press the [

®

] softkey.

3.

Press the [SYSTEM TIMING] softkey.

This screen displays the total foreground and critical foreground execution

times. For both durations, the control displays a rolling average time and

maximum time. To reset the maximum time value, press the [RESET]

softkey or cycle power to the control.