Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 580

Advertising
background image

Probing Parameters

Chapter 31

31-2

Function

The value entered for this parameter is the probe length used for probe

length compensation in G37’s cycles. Probe length is the distance from the

tool Gauge Point on the tool holder to the center of the probe radius, as

measured only along the axis that the probe extends.

For example, if the probe extends along the Z axis, but is mounted off

center from the tool Gauge Point, the Probe Length Compensation amount

is only the amount that it extends along the Z axis.

Axis

Parameter Number

Single Process

Process 1

Process 2

All

[600]

[20600]

[21600]

Range

0.00000 to 1270.00000 mm, or

0.00000 to 50.00000 in.

This is a per process parameter. The value set here applies to all axes

assigned to that process.

Function

The value entered for this parameter is the probe radius used for probe

radius compensation in G31’s, G37’s, and G38’s cycles. Probe radius

refers to the radius of the probe tip. If the documentation for your probe

lists a tip diameter, enter half of that value here.

Axis

Parameter Number

Single Process

Process 1

Process 2

All

[601]

[20601]

[21601]

Range

0.00000 to 254.00000 mm, or

0.00000 to 10.00000 in.

This is a per process parameter. The value set here applies to all axes

assigned to that process.

31.1

Probe Length Compensation

31.2

Probe Radius Compensation