3 dir to move off limit switch – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 112

Advertising
background image

Home Parameters

Chapter 5

5-10

ATTENTION: The axis will only stop when the Axis/Direction

button is released.

After the axis passes three consecutive markers, the control automatically

recalculates the absolute axis position, based on the position after the axis

crosses the three consecutive markers added to the value in Machine Pos.

at DCM Scale 0.

New Abs. Pos. = DCM Physical Abs. Pos. + Machine Pos. at DCM Scale 0

Important: Use Machine Pos. at DCM Scale 0 to determine the

coordinate value at the actual zero marker on your linear scale. This

parameter shifts the scale’s machine coordinate system so the value entered

becomes the actual value of the zero marker. For more information about

this parameter, refer to page 5-23.

Function

This parameter specifies the direction in which the axis moves after it has

tripped the home limit switch.

After the home limit switch is turned “ON,” the axis is commanded to stop.

It decelerates until it is within the range defined by the AMP Inposition

Band parameter.

The axis then proceeds in the direction entered for this parameter.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1002]

(7)

[7002]

(2)

[2002]

(8)

[8002]

(3)

[3002]

(9)

[9002]

(4)

[4002]

(10)

[10002]

(5)

[5002]

(11)

[11002]

(6)

[6002]

(12)

[12002]

Range

Selection

Result

(a)

Negative direction off switch

(b)

Positive direction off switch

5.1.3

Dir to Move Off Limit Switch

Advertising