Interrupt Paramacros
Chapter 26
26-6
Parameter
Parameter
Number
Interrupt 0 service action
[124]
Interrupt 1 service action
[125]
Interrupt 2 service action
[126]
Interrupt 3 service action
[127]
Range
Selection
Result
(a)
Immediate
(b)
Delayed
Notes
This is a global parameter. The value set here applies to all axes
and processes.
These subsections describe grinder-specific AMP parameters that are used
for dress interrupts:
Parameter:
Page:
Dress interrupt trigger method
26-6
Dress interrupt routine call
26-7
Function
Important: This parameter is available only for grinder controls.
Use this parameter to configure the type of signal used to trigger the
dress-on-demand operation.
These are the two available options:
edge — When a trigger method of edge is selected, the control
recognizes a request for a dressing interrupt macro only if the switch
that calls the dress-on-demand interrupt macro makes a transition from a
false to a true state. If the switch that calls a dressing macro is
inadvertently left on (true) when the dressing macro is enabled, the
control won’t recognize the dressing macro call unless the switch is
turned off and then on again.
26.7
Dressing Interrupts
26.8
Dress Interrupt Trigger
Method