Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 548

Advertising
background image

Interrupt Paramacros

Chapter 26

26-6

Parameter

Parameter

Number

Interrupt 0 service action

[124]

Interrupt 1 service action

[125]

Interrupt 2 service action

[126]

Interrupt 3 service action

[127]

Range

Selection

Result

(a)

Immediate

(b)

Delayed

Notes

This is a global parameter. The value set here applies to all axes

and processes.

These subsections describe grinder-specific AMP parameters that are used
for dress interrupts:

Parameter:

Page:

Dress interrupt trigger method

26-6

Dress interrupt routine call

26-7

Function

Important: This parameter is available only for grinder controls.

Use this parameter to configure the type of signal used to trigger the

dress-on-demand operation.

These are the two available options:

edge — When a trigger method of edge is selected, the control
recognizes a request for a dressing interrupt macro only if the switch

that calls the dress-on-demand interrupt macro makes a transition from a

false to a true state. If the switch that calls a dressing macro is

inadvertently left on (true) when the dressing macro is enabled, the

control won’t recognize the dressing macro call unless the switch is

turned off and then on again.

26.7

Dressing Interrupts

26.8

Dress Interrupt Trigger

Method

Advertising