Servo Parameters

Chapter 7

7-74

Table 7.E

Velocity Integral Gain Values for Standard Motors with Absolute Encoders

MOTOR:LOAD

INERTIA

8500 MOTOR TYPES

RATIO

8500

A1C

8500

A2C

8500

B1C

8500

B2C

8500

B3C

8500

A1D

8500

A2D

8500

A3D

8500

B1D

8500

B2D

1 : 0

82

70

94

94

94

82

74

72

94

94

1 : 1

164

141

188

188

188

164

148

144

188

188

1 : 2

246

211

293

293

293

246

222

215

293

293

1 : 3

469

469

469

469

469

469

469

469

469

469

If a nonstandard motor is to be used, the initial value for this parameter

must be determined through extensive motor testing. For assistance call

Allen-Bradley Commercial Engineering at (440) 646-5000.

Generally, if set too high, the axis is underdampened and oscillation

results. If set too low, the axis is overdampened and requires too much

time to reach speed.

Axis

Parameter

Number

Axis

Parameter

Number

(1)

[1800]

(7)

[7800]

(2)

[2800]

(8)

[8800]

(3)

[3800]

(9)

[9800]

(4)

[4800]

(10)

[10800]

(5)

[5800]

(11)

[11800]

(6)

[6800]

(12)

[12800]

Range

33 to 32768 (8500 digital systems)

0 to 65535 (other systems)

Notes

This parameter must be set independently for each servo.

For assistance on determining the optimal velocity proportional gain

amount refer to the tuning procedure in appendix A of this manual.