Feedrate Parameters

Chapter 9

9-5

Function

This parameter determines whether the Rapid Feedrate Override switch

affects the Feedrate when Dry Run is active. Note that Dry Run replaces

all feedrates programmed with an F-word in a program with the Maximum

cutting feedrate. Rapid moves remain at the rapid feedrate. Refer to

chapter 8 of your programming and operation manuals for additional

information on Dry Run mode.

True -- for this parameter means that <RAPID FEEDRATE OVERRIDE>

affects the feedrate for rapid moves when a program is executing in Dry

Run. The programmed feedrates are overridden using <FEEDRATE

OVERRIDE>.

False -- for this parameter means that the Rapid Feedrate Override switch

is ignored when a program is executing in Dry Run mode. Both rapid and

programmed feedrates are overridden using <FEEDRATE OVERRIDE>

on the MTB panel.

Axis

Parameter

Number

All

[66]

Range

Selection

Result

(a)

True

(b)

False

Notes

This is a global parameter. The value entered here applies to all axes.