Spindle 1 Parameters

Chapter 12

12-4

Function

This parameter determines whether the DAC output is a gradual voltage

ramp or a voltage step. For this parameter:

If you select:

then:

ON

any change in DAC output voltages is made as a ramp-up or ramp-down.

The actual spindle ramp duration is selected using the Dev. Detection

Filter Time

parameter (if your system does not have the solid tapping

option). The actual spindle ramp duration is selected using the ACC time

for Spindle 1, Gear __

if your system has the solid tapping feature (this is

used if your system has the solid tapping option and does not mean you

must be using the solid tapping feature to get the ramp). The max speed

for the ramp is determined from your setting of MAX. Spindle Speed-Gear

__ . Thus a different ramp is created for each gear range.

OFF

changes in DAC output voltages are made immediately as one step

50

100

150 Duration (in ms)

LINEAR

Acceleration

ACC/DEC Ramp

(4 rpm/ms)

Max Spindle Speed

for Gear - 1

600RPM

0

If your system:

Your ramp duration is set with:

Your RPM max over that duration is

set with

has the solid tapping

option

ACC time for Spindle 1, Gear __

(in solid tapping parameter group)

Max Tapping Speed -- Gear __

(in solid tapping parameter group)

does not have the solid

tapping option

Spindle DAC Output Ramping

(in spindle parameter group)

Max Spindle Speed -- Gear __

(in spindle parameter group)

Spindle

Parameter

Number

1

[803]

12.2

Spindle DAC Output

Ramping

Advertising