Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 721

Advertising
background image

Patch AMP

Chapter 41

41-19

Parameter

Patch AMP Value

Default Value

Parameter Name

1670

2670

3670

Max % rated torque (+)

200 %

0 to 200%

1680

2680

3680

Feed Forward Percent

0 %

0 to 100%

1690

2690

3690

Torque Offset Percentage

0 %

0 to 100%

1700

2700

3700

Torque Offset Direction

Minus

1 -- Plus

--1 -- Minus

1710

2710

3710

Initial Gain of Position Loop

1.00000

0.00000 to 30.00000

1720

2720

3720

Position Loop Gain Break Ratio

1.000000

0.000000 to 1.000000

1730

2730

3730

Gain Break Point

203.20000 mm

0.00000 to 214.10000 mm

1735

2735

3735

Inposition Band

0.02540 mm

0.00000 to 214.10000 mm

1740

2740

3740

Feedrate Suppression Point

203.20000 mm

0.00000 to 214.10000 mm

1750

2750

3750

Excess Error

203.200000 mm

0.00000 to 214.10000 mm

1755

2755

3755

For internal use only

(do not adjust)

7

1 to 32,767

1780

2780

3780

Servo Amplifier Type

No Servo Amplifier

0 -- No Servo Amplifier

1 -- 3 servo (8520--AA12) :CNA1

2 -- 3 servo (8520--AA12) :CNA2

3 -- 3 servo (8520--AA12) :CNA3

4 -- 2 servo (8520--AA6 :CNA1

5 -- 2 servo (8520--AA6 :CNA2

6 -- single axis (8520--AA21)

8 -- 3 servo (8520--AA12), both modules

9 -- 2 servo (8520--AA6), both modules

10 -- 2 of 3 servo (8520-AA12) :CNA1

11 -- 2 of 3 servo (8520--AA12) :CNA2

12 -- 1 of 3 servo (8520-AA12) :any

13 -- 1 of 2 servo (8520--AA6) :either

14 -- 1394 -- AM03 (2 kW module)

15 -- 1394 -- AM03 (3 kW module)

16 -- 1394 -- AM07 (5 kW module)

Advertising