Jog Parameters
Chapter 8
8-15
Function
The value specified for this parameter is equal to the distance that an
incremental jog move travels when <SPEED/MULTIPLY> on the MTB
panel is set to MEDL X10.
Axis
Parameter Number
Axis
Parameter Number
(1)
[1361]
(7)
[7361]
(2)
[2361]
(8)
[8361]
(3)
[3361]
(9)
[9361]
(4)
[4361]
(10)
[10361]
(5)
[5361]
(11)
[11361]
(6)
[6361]
(12)
[12361]
Range
Smallest Jog Increment to Third Increment value
The minimum and maximum values that may be set for this parameter are
dependant on the values set for the parameters “Smallest Jog Increment”
and “Third Jog Increment.”
Notes
You must set this parameter independently for each axis.
The default setting for <SPEED/MULTIPLY> on the pushbutton MTB
panel is LOW X1.
8.4.2
Second Jog Increment