Jog Parameters

Chapter 8

8-15

Function

The value specified for this parameter is equal to the distance that an

incremental jog move travels when <SPEED/MULTIPLY> on the MTB

panel is set to MEDL X10.

Axis

Parameter Number

Axis

Parameter Number

(1)

[1361]

(7)

[7361]

(2)

[2361]

(8)

[8361]

(3)

[3361]

(9)

[9361]

(4)

[4361]

(10)

[10361]

(5)

[5361]

(11)

[11361]

(6)

[6361]

(12)

[12361]

Range

Smallest Jog Increment to Third Increment value

The minimum and maximum values that may be set for this parameter are

dependant on the values set for the parameters “Smallest Jog Increment”

and “Third Jog Increment.”

Notes

You must set this parameter independently for each axis.

The default setting for <SPEED/MULTIPLY> on the pushbutton MTB

panel is LOW X1.

8.4.2

Second Jog Increment