Power-up G-code Parameters

Chapter 19

19-13

Function

Use this parameter to select the default G-code for modal group 10. You

can use this parameter for lathe/mill applications only; however, this

parameter is not active on lathe A.

The selected G-code specifies whether the control operates under G98 Init

Level Return or under G99 R Point Level Return at power-up or reset.

Lathe

A

Lathe

B

Lathe

C

Mill

Control

Active Mode

------

G98

G98

G98

Init Level Return

------

G99

G99

G99

R Point Level Return

Axis

Parameter Number

Single Process

Process 1

Process 2

All

[530]

[20530]

[21530]

Range

Selection

Result

(a)

Init Level Return

(b)

R Point Level Return

Notes

This is a global parameter; the value set here applies to all axes.

For dual--processing controls, this is a per process parameter. The value set

in the parameter applies to all of the axes assigned to that process.

19.12

PTO G-code for

Modal Group 10

Advertising