5 highest jog speed – Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual
Page 270
Jog Parameters
Chapter 8
8-12
Function
The value specified for this parameter is equal to the speed at which a
continuous jog move takes place when <SPEED/MULTIPLY> on the
MTB panel is set to HIGH X10000.
Axis
Parameter
Number
Axis
Parameter
Number
(1)
[1374]
(7)
[7374]
(2)
[2374]
(8)
[8374]
(3)
[3374]
(9)
[9374]
(4)
[4374]
(10)
[10374]
(5)
[5374]
(11)
[11374]
(6)
[6374]
(12)
[12374]
Range
Fourth Jog Speed to 243840.00000 mmpm
or
Fourth Jog Speed to 9600.00000 ipm
The minimum and maximum values that may be set for this parameter are
dependant on the value set for the parameter’s “Fourth Jog Speed” and
“System Max.”
Set each parameter independently for each axis.
Notes
This is a global parameter. The value set here applies to all axes.
The default setting for <SPEED/MULTIPLY> on the pushbutton MTB
panel is LOW X1.
8.3.5
Highest Jog Speed