Rockwell Automation 8520-ARM2 9/Series CNC AMP Reference Manual Documentation Set User Manual

Page 693

Advertising
background image

Tuning AMP at the Machine

Chapter 40

40-15

When the

{SPNDL PARAM}

softkey is pressed, this screen is displayed

on the operator panel CRT:

ENTER VALUE:

SPINDLE PARAMETERS

MAX OUTPUT [VOLTS]

GEAR RANGE 1

10.000

GEAR RANGE 2

10.000

GEAR RANGE 3

10.000

GEAR RANGE 4

10.000

GEAR RANGE 5

10.000

GEAR RANGE 6

10.000

GEAR RANGE 7

10.000

GEAR RANGE 8

10.000

REPLCE

VALUE

ADD TO

VALUE

UPDATE

& EXIT

QUIT

NEXT

SPINDL

When the control displays this screen, the cursor will be shown on

the value GEAR RANGE 1 in the MAX OUTPUT column.

3.

Use the up or down cursor keys to highlight the spindle parameter

value that is to be changed.

To replace the current spindle parameter value:

press the

{REPLCE VALUE}

softkey

cursor to the position you want

key-in the new value

press

[TRANSMIT]

To add to the current spindle parameter value:

press the

{ADD TO VALUE}

softkey

cursor to the position you want

key-in the new value

press

[TRANSMIT]

Advertising