Chapter

10

10-1

Acc/Dec Parameters

This chapter covers the acceleration and deceleration AMP parameters for
the control.

Use acceleration and deceleration (Acc/Dec) parameters to control the

method and rate of speed change when an axis is starting or stopping.

When you select the “Acc/Dec Parameters” group from the main menu

screen in the AMP application, the workstation displays this screen:

Proj:

AMPTEST

Appl:

AMP

Util:

Edit

F1-File

F2-Axis

F3-Options

F4-Quick Edit!

F5-Process

Type:

Lathe

AXIS :X

-

linear

File :

TEST

- Acc/Dec Parameters -

Positioning ACC/DEC mode

: Linear or S-Curve as per G-code

Velocity step for ACC/DEC (1)

: 254.00000 mmpm

Linear Acceleration Ramp (1)

: 1524.00000 mmpm/s

Linear Deceleration Ramp (1)

: 1524.00000 mmpm/s

S-Curve Acceleration Ramp (1)

: 1524.00000 mmpm/s

S-Curve Deceleration Ramp (1)

: 1524.00000 mmpm/s

Manual Delay Constant (1)

: 3

Programmed Delay Constant

: 1

Manual ACC/DEC mode

: Exponential

Axis Jerk (1)

: 304.8000 mmpm/s/s

Minimum Programmable Jerk (1)

: 304.8000 mmpm/s/s

This chapter covers these Acc/Dec parameters:

Parameter:

Page:

Positioning Acc/Dec Mode

10-3

Velocity Step for Acc/Dec

10-7

Linear Acceleration Ramp

10-8

Linear Deceleration Ramp

10-9

S--Curve Acceleration Ramp

10-11

S--Curve Deceleration Ramp

10-13

Manual Delay Constant

10-14

Programmed Delay Constant

10-17

Manual Acc/Dec Mode

10-19

Axis Jerk

10-21

Minimum Programmable Jerk

10-23

10.0

Chapter Overview