3.7 Load Monit
o
ri
ng
Control parameter 8 “Load monitoring settings”
Factor for torque limit value 1, 2
Factor for work limit value
Limit value = reference value * factor for limit value
Minimum torque [% of rated torque]: Reference values below
this value are raised to this minimum torque value. This prevents
that limit values are exceeded as a result of minor torque
differences.
Maximum file size [KB]: If the data during measured value
registration exceed the maximum file size, the “oldest” values are
overwritten. Approximate value: 12 KB for one component per
minute of program-run time.
Control parameter 15 “bit codes for load monitoring”:
Assigns the bits number used in G995 to the drives (logical axes).