17 configuring turn plus, General settings – HEIDENHAIN CNC Pilot 4290 V7.1 User Manual

Page 549

Advertising
background image

HEIDENHAIN CNC PILOT 4290

549

6.1

7

Configur

ing TURN PLUS

6.17 Configuring TURN PLUS

With the “configuration” you change and manage the display and
input variants.

General settings

Selection:

U

Select “Configuration > Change.”

U

Press “Settings.” TURN PLUS opens the “Settings” dialog box.

“Settings” dialog box

„

Zoom behavior:

„

Dynamic: Adapts the contour graphics to the window size.

„

Static: Adapts the contour graphics to the window size when the
contour is loaded; this setting is maintained.

„

Level ID (designations of the coordinate axes):

„

Display

„

Do not display

„

Point grid in background:

„

Display

„

Do not display

„

X value input (for basic elements and form elements of the turning
contour):

„

Diameter: Entries are diameter values.

„

Radius: Entries are radius values.

„

With help graphic (for illustrating the input parameters):

„

Yes: Display help graphics.

„

No: Do not display help graphics.

„

Start point autom.:

„

Yes: Upon calling the finished part contour entry, TURN PLUS
branches to the entry of the contour starting point. The “DXF
Import” soft key is not available.

„

No: After the finished part contour entry is called, you can choose
whether you want to import a finished part contour or DXF
contour, or whether you will enter the contour manually.

X value input: With standard forms for workpiece blank
description, X values always function as diameter values.
X/XE coordinates on contours for C/Y axis machining
always function as radius values.

Advertising