4 control parameters, General control parameters – HEIDENHAIN CNC Pilot 4290 V7.1 User Manual

Page 577

Advertising
background image

HEIDENHAIN CNC PILOT 4290

577

7.

4 Contr

o

l P

a

ra

met

e

rs

7.4 Control Parameters

General control parameters

General control parameters

1

Settings

„

Suppressing printer output: With the PRINTA command in the NC program you can output data to a printer
(see also control parameter 40).

„

0: Suppress the output

„

1: Enable the output

„

Metric / Inches: Setting for the unit of measure.

„

0: Metric

„

1: Inches

„

Format of the position displays (actual value displays).

„

0: Format 4.3 (4 integral, 3 decimal places)

„

1: Format 3.4 (3 integral, 4 decimal places)

Notes:

„

With DIN PLUS programs, the unit of measure defined in the program head is decisive — regardless of the
unit of measure set here.

„

Restart the CNC PILOT whenever you have changed the unit of measure.

8

Settings for load monitoring

Calculation of limit values: Limit value = reference value * factor for limit value

Evaluation: Load monitoring

„

Factor of torque limit 1

„

Factor of torque limit 2

„

Factor of working limit value

„

Minimum torque [% of rated torque]: Reference values below this value are raised to this minimum torque
value. This prevents that limit values are exceeded as a result of minor torque differences.

„

Maximum file size [KB]: If the data during measured value registration exceed the maximum file size, the
“oldest” values are overwritten.
Rule of thumb: One component requires approx. 12 KB per minute of program run time.

10

Post-process measuring

Evaluation: Post-process measuring

„

Switching measurement on/off

„

0: Post-process measurement off

„

1: Post-process measurement on. The CNC PILOT is ready to receive data.

„

Type of measurement

„

1: Post-process measuring

„

Measured value coupling

„

0: New measured values overwrite old measured values.

„

1: New measured values are not received until the old measured values are evaluated.

Note: In control parameters 40, ..., the serial interface is selected and the interface parameters are defined.