background image

96

3.5 A

u

to

matic Mode

Post-process measuring status

Post-process measuring means that the workpiece is measured
outside the lathe and that the results are transferred to the CNC
PILOT. The “PPM Info” dialog box contains information on the status
of the measured values, displays the transferred results, and allows
initialization of communication with the measuring device.

Operation of “post-process measuring”:

U

Select Display > PPM Status

U

The PPM Info dialog box provides information on the status of the
measured values and the most recently transferred results.

U

If you select “Init,” the post-process measuring function is re-
initialized and all measured values are deleted.

PPM Info dialog box:

„

Measured-value coupling (same as control parameter 10)

„

Off: Measuring results are immediately transferred. Previous
values are overwritten.

„

On: Measuring results are not transferred until the previous
results have been processed.

„

Measured values valid: Status of the measured values (after the
measured values have been transferred with G915, the status “No”
is displayed).

„

#939: Total result of last measurement

„

#940..956: Measuring results last transferred by the measuring
function

The post-process measuring function saves the measured
values received in the clipboard. The PPM Info dialog box
displays in #939..956 the values contained in the
clipboard—not the variables.

Advertising