LI/O Function

4-21

*

The linearity of the analog input is guaranteed only within the range of +/-12.0V.

Analog Output

Analog
Input Circuit

Register Number

IW0001 (default) Setting is possible in the Module Configuration Definition
Screen.

Item

Content

D/A Output
Resolution

+15 Bit 0-±10.5V
16Bit over a +/-10V range, or 328mV

Resolution

V Data = Output RegisterData

×10.75/32767

Output Register Data = V Data

×32767/10.75

Item

Content

12V

1.8kΩ(1/2W)or higher

3

1

25HP-10B

2kΩ

2

100:1

V-REF

Approx.

14kΩ

SG

0V

SGDH

5

6

32767

-32768

+10.75

-10.75

V

+10

30480

-30481