Analog output – Yaskawa MP940 Reference Manual User Manual
Page 112
Advertising
MotionSuite™ MP940 Machine Controller Reference Manual
LI/O Function
4-21
*
The linearity of the analog input is guaranteed only within the range of +/-12.0V.
Analog Output
Analog
Input Circuit
Register Number
IW0001 (default) Setting is possible in the Module Configuration Definition
Screen.
Item
Content
D/A Output
Resolution
+15 Bit 0-±10.5V
16Bit over a +/-10V range, or 328mV
Resolution
V Data = Output RegisterData
×10.75/32767
Output Register Data = V Data
×32767/10.75
Item
Content
12V
1.8kΩ(1/2W)or higher
3
1
25HP-10B
2kΩ
2
100:1
V-REF
Approx.
14kΩ
SG
0V
SGDH
5
6
32767
-32768
+10.75
-10.75
V
+10
30480
-30481
-10